Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.211
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 10504, 2024 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-38714788

RESUMO

We compared cardiovascular parameters obtained with the Mobil-O-Graph and functional capacity assessed by the Duke Activity Status Index (DASI) before and after Heart Transplantation (HT) and also compared the cardiovascular parameters and the functional capacity of candidates for HT with a control group. Peripheral and central vascular pressures increased after surgery. Similar results were observed in cardiac output and pulse wave velocity. The significant increase in left ventricular ejection fraction (LVEF) postoperatively was not followed by an increase in the functional capacity. 24 candidates for HT and 24 controls were also compared. Functional capacity was significantly lower in the HT candidates compared to controls. Stroke volume, systolic, diastolic, and pulse pressure measured peripherally and centrally were lower in the HT candidates when compared to controls. Despite the significant increase in peripheral and central blood pressures after surgery, the patients were normotensive. The 143.85% increase in LVEF in the postoperative period was not able to positively affect functional capacity. Furthermore, the lower values of LVEF, systolic volume, central and peripheral arterial pressures in the candidates for HT are consistent with the characteristics signs of advanced heart failure, negatively impacting functional capacity, as observed by the lower DASI score.


Assuntos
Transplante de Coração , Análise de Onda de Pulso , Volume Sistólico , Humanos , Transplante de Coração/métodos , Masculino , Projetos Piloto , Feminino , Pessoa de Meia-Idade , Volume Sistólico/fisiologia , Adulto , Pressão Sanguínea/fisiologia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Função Ventricular Esquerda/fisiologia , Aorta/cirurgia , Aorta/fisiopatologia , Débito Cardíaco/fisiologia
2.
Acta Biochim Pol ; 71: 12377, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38721303

RESUMO

Background: Goal-directed fluid therapy, as a crucial component of accelerated rehabilitation after surgery, plays a significant role in expediting postoperative recovery and enhancing the prognosis of major surgical procedures. Methods: In line with this, the present study aimed to investigate the impact of target-oriented fluid therapy on volume management during ERAS protocols specifically for gastrointestinal surgery. Patients undergoing gastrointestinal surgery at our hospital between October 2019 and May 2021 were selected as the sample population for this research. Results: 41 cases of gastrointestinal surgery patients were collected from our hospital over 3 recent years. Compared with T1, MAP levels were significantly increased from T2 to T5; cardiac output (CO) was significantly decreased from T2 to T3, and significantly increased from T4 to T5; and SV level was significantly increased from T3 to T5. Compared with T2, HR and cardiac index (CI) were significantly elevated at T1 and at T3-T5. Compared with T3, SVV was significantly decreased at T1, T2, T4, and T5; CO and stroke volume (SV) levels were increased significantly at T4 and T5. In this study, pressor drugs were taken for 23 days, PACU residence time was 40.22 ± 12.79 min, time to get out of bed was 12.41 ± 3.97 h, exhaust and defecation time was 18.11 ± 7.52 h, and length of postoperative hospital stay was 4.47 ± 1.98 days. The average HAMA score was 9.11 ± 2.37, CRP levels were 10.54 ± 3.38 mg/L, adrenaline levels were 132.87 ± 8.97 ng/L, and cortisol levels were 119.72 ± 4.08 ng/L. Prealbumin levels were 141.98 ± 10.99 mg/L at 3 d after surgery, and 164.17 ± 15.84 mg/L on the day of discharge. Lymphocyte count was 1.22 ± 0.18 (109/L) at 3 d after surgery, and 1.47 ± 0.17 (109/L) on the day of discharge. Serum albumin levels were 30.51 ± 2.28 (g/L) at 3 d after surgery, and 33.52 ± 2.07 (g/L) on the day of discharge. Conclusion: Goal-directed fluid therapy (GDFT) under the concept of Enhanced Recovery After Surgery (ERAS) is helpful in volume management during radical resection of colorectal tumors, with good postoperative recovery. Attention should be paid to the influence of pneumoperitoneum and intraoperative posture on GDFT parameters.


Assuntos
Procedimentos Cirúrgicos do Sistema Digestório , Hidratação , Humanos , Hidratação/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos do Sistema Digestório/métodos , Procedimentos Cirúrgicos do Sistema Digestório/reabilitação , Idoso , Recuperação Pós-Cirúrgica Melhorada , Volume Sistólico , Tempo de Internação/estatística & dados numéricos , Débito Cardíaco , Adulto
3.
Artigo em Inglês | MEDLINE | ID: mdl-38684395

RESUMO

PURPOSE: Goal-directed perfusion (GDP) refers to individualized goal-directed therapy using comprehensive monitoring and optimizing the delivery of oxygen during cardiopulmonary bypass (CPB). This study aims to determine whether the intraoperative GDP protocol method has better outcomes compared to conventional methods. METHODS: We searched the PubMed, Central, and Scopus databases up to October 12, 2023. We primarily examined the GDP protocol in adult cardiac surgery, using CPB with oxygen delivery index (DO2I) and cardiac index (CI) as the main parameters. RESULTS: In all, 1128 participants from seven studies were included in our analysis. The results showed significant differences in the duration of intensive care unit (ICU) stays (p = 0.01), with a mean difference of -0.33 (-0.59 to 0.07), and hospital length of stay (LOS) (p = 0.0002), with a mean difference of -0.84 (-1.29 to -0.39). There was also a notable reduction in postoperative complications (p <0.00001), odds ratio (OR) of 0.43 (0.32-0.60). However, there was no significant decrease in mortality rate (p = 0.54), OR of 0.77 (0.34-1.77). CONCLUSION: Postoperative acute kidney injury and ICU and hospital LOS are significantly reduced when GDP protocols with indicators of flow management, oxygen delivery index, and CI are used in intraoperative cardiac surgery using CPB.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ponte Cardiopulmonar , Tempo de Internação , Humanos , Ponte Cardiopulmonar/efeitos adversos , Resultado do Tratamento , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/mortalidade , Oxigênio/sangue , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Masculino , Idoso , Pessoa de Meia-Idade , Cuidados Intraoperatórios , Feminino , Fatores de Tempo , Monitorização Intraoperatória/métodos , Valor Preditivo dos Testes , Tomada de Decisão Clínica , Débito Cardíaco
4.
J Appl Physiol (1985) ; 136(5): 1276-1283, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38602000

RESUMO

In patients with chronic obstructive pulmonary disease (COPD), pulmonary vascular dysfunction and destruction are observable before the onset of detectable emphysema, but it is unknown whether this is associated with central hypovolemia. We investigated if patients with COPD have reduced pulmonary blood volume (PBV) evaluated by 82Rb-positron emission tomography (PET) at rest and during adenosine-induced hyperemia. This single-center retrospective cohort study assessed 6,301 82Rb-PET myocardial perfusion imaging (MPI) examinations performed over a 6-yr period. We compared 77 patients with COPD with 44 healthy kidney donors (controls). Cardiac output ([Formula: see text]) and mean 82Rb bolus transit time (MBTT) were used to calculate PBV. [Formula: see text] was similar at rest (COPD: 3,649 ± 120 mL vs. control: 3,891 ± 160 mL, P = 0.368) but lower in patients with COPD compared with controls during adenosine infusion (COPD: 5,432 ± 124 mL vs. control: 6,185 ± 161 mL, P < 0.050). MBTT was shorter in patients with COPD compared with controls at rest (COPD: 8.7 ± 0.28 s vs. control: 11.4 ± 0.37 s, P < 0.001) and during adenosine infusion (COPD: 9.2 ± 0.28 s vs. control: 10.2 ± 0.37 s, P < 0.014). PBV was lower in patients with COPD, even after adjustment for body surface area, sex, and age at rest [COPD: 530 (29) mL vs. 708 (38) mL, P < 0.001] and during adenosine infusion [COPD: 826 (29) mL vs. 1,044 (38) mL, P < 0.001]. In conclusion, patients with COPD show evidence of central hypovolemia, but it remains to be determined whether this has any diagnostic or prognostic impact.NEW & NOTEWORTHY The present study demonstrated that patients with chronic obstructive pulmonary disease (COPD) exhibit central hypovolemia compared with healthy controls. Pulmonary blood volume may thus be a relevant physiological and/or clinical outcome measure in future COPD studies.


Assuntos
Volume Sanguíneo , Tomografia por Emissão de Pósitrons , Doença Pulmonar Obstrutiva Crônica , Humanos , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Volume Sanguíneo/fisiologia , Tomografia por Emissão de Pósitrons/métodos , Pulmão/fisiopatologia , Pulmão/diagnóstico por imagem , Radioisótopos de Rubídio , Imagem de Perfusão do Miocárdio/métodos , Adenosina/administração & dosagem , Débito Cardíaco/fisiologia
5.
BMC Anesthesiol ; 24(1): 88, 2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38431582

RESUMO

BACKGROUND: Tracking preload dependency non-invasively to maintain adequate tissue perfusion in the perioperative period can be challenging.The effect of phenylephrine on stroke volume is dependent upon preload. Changes in stroke volume induced by phenylephrine administration can be used to predict preload dependency. The change in the peripheral perfusion index derived from photoplethysmography signals reportedly corresponds with changes in stroke volume in situations such as body position changes in the operating room. Thus, the peripheral perfusion index can be used as a non-invasive potential alternative to stroke volume to predict preload dependency. Herein, we aimed to determine whether changes in perfusion index induced by the administration of phenylephrine could be used to predict preload dependency. METHODS: We conducted a prospective single-centre observational study. The haemodynamic parameters and perfusion index were recorded before and 1 and 2 min after administering 0.1 mg of phenylephrine during post-induction hypotension in patients scheduled to undergo surgery. Preload dependency was defined as a stroke volume variation of ≥ 12% before phenylephrine administration at a mean arterial pressure of < 65 mmHg. Patients were divided into four groups according to total peripheral resistance and preload dependency. RESULTS: Forty-two patients were included in this study. The stroke volume in patients with preload dependency (n = 23) increased after phenylephrine administration. However, phenylephrine administration did not impact the stroke volume in patients without preload dependency (n = 19). The perfusion index decreased regardless of preload dependency. The changes in the perfusion index after phenylephrine administration exhibited low accuracy for predicting preload dependency. Based on subgroup analysis, patients with high total peripheral resistance tended to exhibit increased stroke volume following phenylephrine administration, which was particularly prominent in patients with high total peripheral resistance and preload dependency. CONCLUSION: The findings of the current study revealed that changes in the perfusion index induced by administering 0.1 mg of phenylephrine could not predict preload dependency. This may be attributed to the different phenylephrine-induced stroke volume patterns observed in patients according to the degree of total peripheral resistance and preload dependency. TRIAL REGISTRATION: University Hospital Medical Information Network (UMIN000049994 on 9/01/2023).


Assuntos
Anestesia Geral , Índice de Perfusão , Humanos , Fenilefrina/farmacologia , Débito Cardíaco , Estudos Prospectivos , Volume Sistólico , Hidratação , Pressão Sanguínea
6.
Eur J Pediatr ; 183(5): 2183-2192, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38376594

RESUMO

We aimed to establish reference ranges for USCOM parameters in preterm infants, determine factors that affect cardiac output, and evaluate the measurement repeatability. This retro-prospective study was performed at Fondazione IRCCS San Gerardo dei Tintori, Monza, Italy. We included infants below 32 weeks of gestational age (GA) and/or 1500 g of birth weight (BW). We excluded infants with congenital heart diseases or hemodynamic instability. Measurements were performed at 3 ± 1, 7 ± 2, and 14 ± 2 postnatal days. We analyzed 204 measurements from 92 patients (median GA = 30.57 weeks, BW = 1360 g). The mean (SD) cardiac output (CO) was 278 (55) ml/min/kg, cardiac index (CI) was 3.1 (0.5) L/min/m2, and systemic vascular resistance (SVRI) was 1292 (294) d*s*cm-5/m2. CO presented a negative correlation with postmenstrual age (PMA), while SVRI presented a positive correlation with PMA. The repeatability coefficient was 31 ml/kg/min (12%).  Conclusion: This is the first study describing reference values for USCOM parameters in hemodynamically stable preterm infants and factors affecting their variability. Further studies to investigate the usefulness of USCOM for the longitudinal assessment of patients at risk for cardiovascular instability or monitoring the response to therapies are warranted. What is Known: • The ultrasonic cardiac output monitoring (USCOM) has been widely used on adult and pediatric patients and reference ranges for cardiac output (CO) by USCOM have been established in term infants. What is New: • We established reference values for USCOM parameters in very preterm and very-low-birth-weight infants; the reference ranges for CO by USCOM in the study population were 198-405 ml/kg/min. • CO normalized by body weight presented a significant negative correlation with postmenstrual age (PMA); systemic vascular resistance index presented a significant positive correlation with PMA.


Assuntos
Débito Cardíaco , Recém-Nascido Prematuro , Humanos , Recém-Nascido , Débito Cardíaco/fisiologia , Masculino , Feminino , Valores de Referência , Estudos Prospectivos , Estudos Retrospectivos , Hemodinâmica/fisiologia , Reprodutibilidade dos Testes , Idade Gestacional , Monitorização Fisiológica/métodos , Resistência Vascular/fisiologia
7.
Ulus Travma Acil Cerrahi Derg ; 30(2): 90-96, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38305657

RESUMO

BACKGROUND: In critically ill patients, especially those with septic shock, fluid management can be a challenging aspect of clinical care. One of the primary steps in treating patients with hemodynamic instability is optimizing intravascular volume. The Passive Leg Raising (PLR) maneuver is a reliable test for assessing fluid responsiveness, as demonstrated by numerous studies and meta-analyses. However, its use requires the measurement of cardiac output, which is often complex and may necessitate clinician experience and specialized equipment. End-Tidal Carbon Dioxide (ETCO2) measurement is relatively easy and is generally stable under steady metabolic conditions. It depends on the body's CO2 production, diffusion of CO2 from the lungs into the bloodstream, and cardiac output. If the other two parameters (metabolic conditions and minute ventilation) are constant, ETCO2 can provide information about cardiac output. The aim of the present study is to investigate the sensitivity of ETCO2 measurement in demonstrating fluid responsiveness. METHODS: All patients diagnosed with septic shock and meeting the inclusion criteria were subjected to a passive leg raising test, and cardiac outputs were measured by echocardiography. An increase in cardiac output of 15% or more was considered indicative of the fluid responder group, while patients with an increase below 15% or no increase were classified as the non-responder group. Patients' intensive care unit admission diagnoses, initial laboratory parameters, tidal volume, minute volume before and after the PLR maneuver, mean and systolic blood pressure, heart rate, Pulse Pressure Variation (PPV) values, and ETCO2 values were recorded. RESULTS: Before and after the ETCO2 test, there was no statistically significant difference between the two groups. However, the change in ETCO2 (ΔETCO2) was significantly higher in the responder group. In the non-responder group, ΔETCO2 was 2.57% (0.81), whereas it was 5.71% (2.83) in the responder group (p<0.001). Receiver Operating Characteristic (ROC) analysis was performed for ΔETCO2, baseline Stroke Volume Variation (SVV), ΔSVV, baseline Heart Rate (HR), ΔHR, baseline PPV, and ΔPPV to predict fluid responsiveness. ΔETCO2 predicted fluid responsiveness with a sensitivity of 85% and a specificity of 86% when it was 4% or higher. When ΔETCO2 was 5% or higher, it predicted fluid responsiveness with a specificity of 99.3% and a sensitivity of 75.5%, with an Area Under the Curve (AUC) of 0.89 (95% confidence interval, 0.828-0.961). CONCLUSION: This study demonstrates that in septic patients, ETCO2 during the PLR test can indicate fluid responsiveness with high sensitivity and specificity and can be used as an alternative to cardiac output measurement.


Assuntos
Choque Séptico , Humanos , Choque Séptico/diagnóstico , Choque Séptico/terapia , Dióxido de Carbono/metabolismo , Volume Sistólico/fisiologia , Hemodinâmica , Respiração Artificial , Débito Cardíaco/fisiologia , Hidratação/métodos
8.
Sci Rep ; 14(1): 3617, 2024 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-38351038

RESUMO

Apnoeic oxygenation has experienced a resurgence in interest in critical care and perioperative medicine. However, its effect on cerebral oxygenation and factors influencing it, have not yet been investigated in detail. By using near-infrared spectroscopy, we intended to provide further evidence for the safety of apnoeic oxygenation and to increase our understanding of the association between cerebral perfusion, haemodynamic, respiratory and demographic factors. In this secondary analysis of a prospective randomized controlled noninferiority trial, we recruited 125 patients, who underwent surgery under general anaesthesia with neuromuscular blockade. Arterial blood samples were taken every 2 min for a total of 15 min under apnoeic oxygenation with 100% oxygen. Near-infrared spectroscopy and cardiac output were continuously measured. Statistical analysis was performed using uni- and multivariable statistics. Ninety-one complete data sets were analysed. In six patients the SpO2 fell below 92% (predefined study termination criterion). The significant average increase of cerebral oxygenation was 0.5%/min and 2.1 mmHg/min for the arterial pressure of carbon dioxide (paCO2). The median cardiac output increased significantly from 5.0 l/min (IQR 4.5-6.0) to 6.5 l/min (IQR 5.7-7.5). The most significant effect on cerebral oxygenation was exhibited by the variable paCO2 and non-specific patient factors, followed by cardiac output and paO2. Apnoeic oxygenation proves to have a high safety profile while significantly increasing cerebral oxygenation, paCO2 and cardiac output. In reverse, NIRS might act as a reliable clinical surrogate of paCO2 and cardiac output during stable arterial oxygenation.


Assuntos
Dióxido de Carbono , Respiração Artificial , Humanos , Débito Cardíaco , Oxigênio , Estudos Prospectivos
9.
Int J Cardiol ; 401: 131699, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38182061

RESUMO

BACKGROUND: Cardiogenic shock (CS) is the leading cause of death in patients with myocardial infarction with a mortality rate greater than 50%. Recently, the CS 4 Proteins (CS4P) and CLIP scores have been developed to predict survival in CS patients. However, their impact in acute CS and additional short-term left ventricular (LV) circulatory support as prognostic markers is currently not known. METHODS AND RESULTS: CS was induced in a porcine model by injecting microsphere particles into the left main coronary artery. Mechanical circulatory support was performed by additional percutaneous LV unloading using an Impella microaxial flow-pump for 30 minutes. Serum samples were collected at baseline, following the onset of CS, and additional LV unloading. Serum levels of biomarkers of the CS4P (beta-2-microglobulin, ALDOB, L-FABP, SerpinG1) and the CLIP scores (Cystatin C, Lactate, Interleukin-6, NT-proBNP) were neither different at any time point investigated nor did they correlate with cardiac output. CONCLUSION: The CS4P and CLIP scores do not reflect immediate whole-body dysregulation in acute CS and have not been able to predict the potential reversal following additional short-term mechanical support by LV unloading in our experimental model. The impact of both scores as prognostic markers after the immediate onset of CS and following additional short-term LV unloading to identify patients at greatest risk remains to be determined.


Assuntos
Coração Auxiliar , Infarto do Miocárdio , Humanos , Animais , Suínos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/terapia , Choque Cardiogênico/etiologia , Débito Cardíaco , Biomarcadores , Coração Auxiliar/efeitos adversos , Resultado do Tratamento
10.
Perfusion ; 39(3): 555-563, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36638055

RESUMO

INTRODUCTION: To validate slaughterhouse hearts for ex-situ heart perfusion studies, we compared cold oxygenated machine perfusion in less expensive porcine slaughterhouse hearts (N = 7) to porcine hearts that are harvested following the golden standard in laboratory animals (N = 6). METHODS: All hearts received modified St Thomas 2 crystalloid cardioplegia prior to 4 hours of cold oxygenated machine perfusion. Hearts were perfused with homemade modified Steen heart solution with a perfusion pressure of 20-25 mmHg to achieve a coronary flow between 100-200 mL/min. Reperfusion and testing was performed for 4 hours on a normothermic, oxygenated diluted whole blood loaded heart model. Survival was defined by a cardiac output above 3 L with a mean aortic pressure above 60 mmHg. RESULTS: Both groups showed 100% functional survival, with laboratory hearts displaying superior cardiac function. Both groups showed similar decline in function over time. CONCLUSION: We conclude that the slaughterhouse heart can be used as an alternative to laboratory hearts and provides a cost-effective method for future ex-situ heart perfusion studies.


Assuntos
Matadouros , Transplante de Coração , Animais , Suínos , Coração , Parada Cardíaca Induzida , Perfusão/métodos , Débito Cardíaco , Preservação de Órgãos/métodos
11.
Curr Opin Anaesthesiol ; 37(1): 1-9, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38085877

RESUMO

PURPOSE OF REVIEW: Cardiac surgery has traditionally relied upon invasive hemodynamic monitoring, including regular use of pulmonary artery catheters. More recently, there has been advancement in our understanding as well as broader adoption of less invasive alternatives. This review serves as an outline of the key perioperative hemodynamic monitoring options for cardiac surgery. RECENT FINDINGS: Recent study has revealed that the use of invasive monitoring such as pulmonary artery catheters or transesophageal echocardiography in low-risk patients undergoing low-risk cardiac surgery is of questionable benefit. Lesser invasive approaches such a pulse contour analysis or ultrasound may provide a useful alternative to assess patient hemodynamics and guide resuscitation therapy. A number of recent studies have been published to support broader indication for these evolving technologies. SUMMARY: More selective use of indwelling catheters for cardiac surgery has coincided with greater application of less invasive alternatives. Understanding the advantages and limitations of each tool allows the bedside clinician to identify which hemodynamic monitoring modality is most suitable for which patient.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Monitorização Hemodinâmica , Humanos , Hemodinâmica , Ecocardiografia Transesofagiana , Ressuscitação , Monitorização Fisiológica , Débito Cardíaco
13.
Cardiol Young ; 34(2): 262-267, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37317547

RESUMO

BACKGROUND: Lifetime radiation exposure for paediatric orthotopic heart transplant (OHT) patients is significant with cardiac catheterisation as the dominant source. Interventional cardiac magnetic resonance is utilised to obtain simultaneous, radiation-free haemodynamics and flow/function measurements. We sought to compare invasive haemodynamic measurements and radiation exposure in traditional cardiac catheterisation, to comprehensive interventional cardiac magnetic resonance. METHODS: Twenty-eight OHT patients who underwent 67 interventional cardiac magnetic resonance procedures at Children's National Hospital were identified. Both invasive oximetry with peripheral oxygen saturation (Fick) and cardiac magnetic resonance phase contrast measurements of pulmonary and systemic blood flow were performed. Systemic and pulmonary blood flow from the two modalities was compared using Bland-Altman, concordance analysis, and inter-reader correlation. A mixed model was implemented to account for confounding variables and repeat encounters. Radiation dosage data were collected for a contemporaneous cohort of orthotopic heart transplant patients undergoing standard, X-ray-guided catheterisation. RESULTS: Simultaneous cardiac magnetic resonance and Fick have poor agreement in our study based on Lin's correlation coefficient of 0.68 and 0.73 for pulmonary and systemic blood flow, respectively. Bland-Altman analysis demonstrated a consistent over estimation of cardiac magnetic resonance cardiac output by Fick. The average indexed dose area product for patients undergoing haemodynamics with endomyocardial biopsy was 0.73 (SD ±0.6) Gy*m2/kg. With coronary angiography added, the indexed dose area product was 14.6 (SD ± 7.8) Gy*m2/kg. CONCLUSIONS: Cardiac magnetic resonancemeasurements of cardiac output/index in paediatric orthotopic heart transplant patients have poor concordance with Fick estimates; however, cardiac magnetic resonance has good internal validity and inter-reader reliability. Radiation doses are small for haemodynamics with biopsy and increase exponentially with angiography, identifying a new target for cardiac magnetic resonance imaging.


Assuntos
Transplante de Coração , Imageamento por Ressonância Magnética , Criança , Humanos , Reprodutibilidade dos Testes , Cateterismo Cardíaco , Oximetria/métodos , Débito Cardíaco/fisiologia , Espectroscopia de Ressonância Magnética
14.
JACC Heart Fail ; 12(1): 117-129, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37632493

RESUMO

BACKGROUND: Patients with heart failure with reduced ejection fraction (HFrEF) have persistent impairments in functional capacity after continuous-flow left ventricular assist device (CF-LVAD) implantation. OBJECTIVES: This study aims to characterize longitudinal changes in exercise hemodynamics and functional capacity among patients with HFrEF before and after CF-LVAD implantation. METHODS: Ten patients underwent 3 invasive cardiopulmonary exercise tests on upright cycle ergometry with pulmonary artery catheterization: 1) Visit 1 before CF-LVAD implantation; 2) Visit 2 after device implantation with CF-LVAD pump speed held constant at baseline speed; and 3) Visit 3 with increases in pump speed during exercise (median: 1,050 rpm [IQR: 750-1,150 rpm] and 220 rpm [IQR: 120-220 rpm] for HeartMate 3 and HeartWare VAD, respectively). Hemodynamics and direct Fick cardiac output were monitored using pulmonary artery catheterization. Gas exchange metrics were determined using indirect calorimetry. RESULTS: Maximal oxygen uptake (Visits 1, 2, and 3: 10.8 ± 2.5 mL/kg/min, 10.7 ± 2.2 mL/kg/min, and 11.5 ± 1.7 mL/kg/min; P = 0.92) did not improve after device implantation. Mean pulmonary arterial and pulmonary capillary wedge pressures increased significantly during submaximal and peak exercise on preimplantation testing (P < 0.01 for rest vs peak exercise) and remained elevated, with minimal change on Visits 2 and 3 regardless of whether pump speed was fixed or increased. CONCLUSIONS: Among patients with HFrEF, cardiovascular hemodynamics and exercise capacity were similar after CF-LVAD implantation, regardless of whether patients exercised at fixed or adjusted pump speeds during exercise. Further research is needed to determine methods by which LVADs may alleviate the HFrEF syndrome after device implantation. (Effect of mechanIcal circulatoRy support ON exercise capacity aMong pAtieNts with heart failure [IRONMAN]; NCT03078972).


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Disfunção Ventricular Esquerda , Humanos , Débito Cardíaco , Teste de Esforço/métodos , Insuficiência Cardíaca/terapia , Hemodinâmica , Volume Sistólico , Função Ventricular Esquerda
16.
J Anesth ; 38(1): 1-9, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37740733

RESUMO

PURPOSE: Several technical aspects of the Fick method limit its use intraoperatively. A data-driven modification of the Fick method may enable its use in intraoperative settings. METHODS: This two-center retrospective observational study included 57 (28 and 29 in each center) patients who underwent off-pump coronary artery bypass graft (OPCAB) surgery. Intraoperative recordings of physiological data were obtained and divided into training and test datasets. The Fick equation was used to calculate cardiac output (CO-Fick) using ventilator-determined variables, intraoperative hemoglobin level, and SvO2, with continuous thermodilution cardiac output (CCO) used as a reference. A modification CO-Fick was derived and validated: CO-Fick-AD, which adjusts the denominator of the original equation. RESULTS: Increased deviation between CO-Fick and CCO was observed when oxygen extraction was low. The root mean square error of CO-Fick was decreased from 6.07 L/min to 0.70 L/min after the modification. CO-Fick-AD showed a mean bias of 0.17 (95% CI 0.00-0.34) L/min, with a 36.4% (95% CI 30.6-44.4%) error. The concordance rates of CO-Fick-AD ranged from 73.3 to 87.1% depending on the time interval and exclusion zone. CONCLUSIONS: The original Fick method is not reliable when oxygen extraction is low, but a modification using data-driven approach could enable continuous estimation of cardiac output during the dynamic intraoperative period with minimal bias. However, further improvements in precision and trending ability are needed.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea , Humanos , Débito Cardíaco/fisiologia , Monitorização Fisiológica , Consumo de Oxigênio , Oxigênio , Termodiluição/métodos
17.
J Clin Monit Comput ; 38(1): 139-146, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37458916

RESUMO

PURPOSE: Pulse Decomposition Analysis (PDA) uses integration of the systolic area of a distally transmitted aortic pulse as well as arterial stiffness estimates to compute cardiac output. We sought to assess agreement of cardiac output (CO) estimation between continuous pulmonary artery catheter (PAC) guided thermodilution (CO-CCO) and a wireless, wearable noninvasive device, (Vitalstream, Caretaker Medical, Charlottesville, VA), that utilizes the Pulse Decomposition Analysis (CO-PDA) method in postoperative cardiac surgery patients in the intensive care unit. METHODS: CO-CCO measurements were compared with post processed CO-PDA measurements in prospectively enrolled adult cardiac surgical intensive care unit patients. Uncalibrated CO-PDA values were compared for accuracy with CO-CCO via a Bland-Altman analysis considering repeated measurements and a concordance analysis with a 10% exclusion zone. RESULTS: 259.7 h of monitoring data from 41 patients matching 15,583 data points were analyzed. Mean CO-CCO was 5.55 L/min, while mean values for the CO-PDA were 5.73 L/min (mean of differences +- SD 0.79 ± 1.11 L/min; limits of agreement - 1.43 to 3.01 L/min), with a percentage error of 37.5%. CO-CCO correlation with CO-PDA was moderate (0.54) and concordance was 0.83. CONCLUSION: Compared with the CO-CCO Swan-Ganz, cardiac output measurements obtained using the CO-PDA were not interchangeable when using a 30% threshold. These preliminary results were within the 45% limits for minimally invasive devices, and pending further robust trials, the CO-PDA offers a noninvasive, wireless solution to complement and extend hemodynamic monitoring within and outside the ICU.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Artéria Pulmonar , Adulto , Humanos , Termodiluição/métodos , Débito Cardíaco , Cateterismo de Swan-Ganz , Procedimentos Cirúrgicos Cardíacos/métodos , Cuidados Críticos , Unidades de Terapia Intensiva , Reprodutibilidade dos Testes
18.
ESC Heart Fail ; 11(1): 189-197, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37885349

RESUMO

AIMS: Patients with high-flow arteriovenous (AV) access are at risk of developing high-output cardiac failure (HOCF) and subsequent hospitalization. However, diagnosing HOCF is challenging and often requires invasive procedures. The role of systemic vascular resistance (SVR) in diagnosing HOCF is underestimated, and its predictive value is limited. Our study aims to identify non-invasive risk factors for HOCF to facilitate early diagnosis and timely surgical interventions. METHODS AND RESULTS: We included 109 patients with high-flow AV access who underwent serial echocardiography. The retrospective cohort was divided into two groups based on their hospitalization due to HOCF. The two groups were matched for age and gender. After a mean follow-up of 25.1 months, 19 patients (17.4%) were hospitalized due to HOCF. The two groups had similar baseline characteristics. However, the HOCF group had a higher value of vascular access blood flow (Qa) (2168 ± 856 vs. 1828 ± 617 mL/min; P = 0.045). Echocardiographic analysis revealed that the HOCF group had more pronounced left ventricular diastolic dysfunction (E/e': 21.1 ± 7.3 vs. 16.2 ± 5.9; P = 0.002), more severe pulmonary hypertension (right ventricular systolic pressure: 41.4 ± 16.7 vs. 32.2 ± 12.8; P = 0.009), a higher Doppler-derived cardiac index (CI) (4.3 ± 0.8 vs. 3.7 ± 1.1; P = 0.031), and a lower Doppler-derived estimated SVR (eSVR) value (5.5 ± 0.3 vs. 6.9 ± 0.2; P = 0.002) than the non-HOCF group. Using multivariable Cox regression analysis, a low eSVR value (<6) emerged as an independent predictor of HOCF hospitalization with a hazard ratio of 9.084 (95% confidence interval, 2.33-35.39; P = 0.001). Receiver operating characteristic curve analysis indicated that CI/eSVR values more accurately predicted HOCF hospitalization [sensitivity: 94.7%, specificity: 51.0%, area under the curve (AUC): 0.75, P < 0.001] than the Qa/cardiac output ratio (AUC: 0.50, P = 0.955), Qa values ≥ 2000 mL/min (AUC: 0.60, P = 0.181), and Qa values indexed for height in metres (AUC: 0.65, P = 0.040). CONCLUSIONS: In patients with high-flow AV access, low eSVR values obtained through non-invasive Doppler echocardiography were associated with a high rate of HOCF hospitalizations. Therefore, routine eSVR screening in these patients might expedite the diagnosis of HOCF.


Assuntos
Insuficiência Cardíaca , Humanos , Estudos Retrospectivos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Débito Cardíaco , Resistência Vascular , Ecocardiografia Doppler
19.
ESC Heart Fail ; 11(2): 1263-1268, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38158705

RESUMO

AIMS: Our aim was to investigate haemodynamics at rest and during exercise in patients with transthyretin cardiomyopathy (ATTR-CM) in light of the 2022 European Society of Cardiology (ESC) and European Respiratory Society (ERS) guidelines on pulmonary hypertension (PH). METHODS AND RESULTS: We performed right heart catheterization (RHC) in 57 subjects with ATTR-CM. The proportion of patients with PH was 77% according to the 2022 guidelines versus 47% when applying the 2015 guidelines. Isolated post-capillary PH and combined pre- and post-capillary PH were most prevalent. Thirty-six patients underwent a supine bicycle cardiopulmonary exercise test during RHC. Exercise-induced PH was defined as an increase in mean pulmonary arterial pressure from rest to exercise per increase in cardiac output (ΔmPAP/ΔCO) of > 3 mmHg/L/min. An increase in pulmonary arterial wedge pressure per change in cardiac output (ΔPAWP/ΔCO) from rest to exercise >2 mmHg/L/min was considered suggestive of post-capillary exercise-induced PH. All but two patients who exercised during RHC developed exercise-induced PH. The median ΔmPAP/ΔCO was 7.2 mmHg/L/min and ΔPAWP/ΔCO was 5.1 mmHg/L/min. The median ΔRAP/ΔCO was 3.6 mmHg/L/min and ΔRAP/ΔPAWP was 0.6 mmHg/L/min. CONCLUSIONS: Most patients with ATTR-CM have isolated post-capillary or combined pre- and post-capillary PH at rest, and almost all patients develop exercise-induced PH with a large post-capillary component. There was a pronounced, but balanced increase in atrial pressures on exercise.


Assuntos
Amiloidose , Hipertensão Pulmonar , Humanos , Hemodinâmica , Débito Cardíaco , Pressão Propulsora Pulmonar
20.
J Crit Care ; 79: 154449, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37857068

RESUMO

BACKGROUND: Passive leg raising (PLR) reliably predicts fluid responsiveness but requires a real-time cardiac index (CI) measurement or the presence of an invasive arterial line to achieve this effect. The plethysmographic variability index (PVI), an automatic measurement of the respiratory variation of the perfusion index, is non-invasive and continuously displayed on the pulse oximeter device. We tested whether PLR-induced changes in PVI (ΔPVIPLR) could accurately predict fluid responsiveness in mechanically ventilated patients with acute circulatory failure. METHODS: This was a secondary analysis of an observational prospective study. We included 29 mechanically ventilated patients with acute circulatory failure in this study. We measured PVI (Radical-7 device; Masimo Corp., Irvine, CA) and CI (Echocardiography) before and during a PLR test and before and after volume expansion of 500 mL of crystalloid solution. A volume expansion-induced increase in CI of >15% defined fluid responsiveness. To investigate whether ΔPVIPLR can predict fluid responsiveness, we determined areas under the receiver operating characteristic curves (AUROCs) and gray zones for ΔPVIPLR. RESULTS: Of the 29 patients, 27 (93.1%) received norepinephrine. The median tidal volume was 7.0 [IQR: 6.6-7.6] mL/kg ideal body weight. Nineteen patients (65.5%) were classified as fluid responders (increase in CI > 15% after volume expansion). Relative ΔPVIPLR accurately predicted fluid responsiveness with an AUROC of 0.89 (95%CI: 0.72-0.98, p < 0.001). A decrease in PVI ≤ -24.1% induced by PLR detected fluid responsiveness with a sensitivity of 95% (95%CI: 74-100%) and a specificity of 80% (95%CI: 44-97%). Gray zone was acceptable, including 13.8% of patients. The correlations between the relative ΔPVIPLR and changes in CI induced by PLR and by volume expansion were significant (r = -0.58, p < 0.001, and r = -0.65, p < 0.001; respectively). CONCLUSIONS: In sedated and mechanically ventilated ICU patients with acute circulatory failure, PLR-induced changes in PVI accurately predict fluid responsiveness with an acceptable gray zone. TRIAL REGISTRATION: ClinicalTrials.govNCT03225378.


Assuntos
Hemodinâmica , Choque , Humanos , Respiração Artificial , Perna (Membro) , Estado Terminal , Estudos Prospectivos , Hidratação , Débito Cardíaco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA